ZN63(VS1)-24 Plateau Type Indoor High Voltage Vacuum Circuit Breaker

The ZN63(VS1)-24 type indoor high-voltage vacuum circuit breaker is an indoor switchgear for three-phase AC 50Hz power systems with a rated voltage of 24kV, serving as a protection and control unit for power grid equipment and industrial and mining enterprise power equipment. It is suitable for occasions requiring frequent operation under rated working current or multiple interruption of short-circuit current.
  • Detail

Overview

The ZN63(VS1)-24 type indoor high-voltage vacuum circuit breaker is an indoor switchgear for three-phase AC 50Hz power systems with a rated voltage of 24kV, serving as a protection and control unit for power grid equipment and industrial and mining enterprise power equipment. It is suitable for occasions requiring frequent operation under rated working current or multiple interruption of short-circuit current. 

This circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body, which can be used as a fixed installation unit or equipped with a dedicated trolley mechanism to function as a withdrawable unit.


Model Meaning

1-1.jpg


Main Technical Parameters

Serial No.ItemUnitData
1Rated VoltagekV24
2Rated Short-time Power Frequency Withstand Voltage (1min)kV65/79 (Phase-to-phase, Phase-to-ground / Break)
3Rated Lightning Impulse Withstand Voltage (Peak)kV125/145 (Phase-to-phase, Phase-to-ground / Break)
4Rated FrequencyHz50
5Rated CurrentA630630 1250630 1250
12501600 20001600 2000
2500 31502500 3150
6Rated Short-circuit Breaking CurrentkA20/2531.540
7Rated Short-time Withstand VoltagekA20/2535.540
8Rated Short-circuit Durations4
9Rated Peak Withstand CurrentkA50/6380100
10Rated Short-circuit Making CurrentkA50/6380100
11Secondary Circuit Power Frequency Withstand Voltage (1min)V200
12Rated Single / Back-to-Back Capacitor Bank Breaking CurrentA630/400 (800/400 for 40kA)
13Rated Capacitor Bank Combination Inrush CurrentkA12.5 (Frequency not greater than 1000Hz)
14Mechanical Lifetimes20000
15Rated Current Breaking Times (Electrical Life)times20000
16Rated Short-circuit Current Breaking Timestimes50(40kA ≤ 30)
17Allowable Cumulative Wear Thickness of Moving and Static Contactsmm3
18Energy Storage Times≤ 10
19Contact Opening Distancemm16±1
20Over Travelmm3.5±0.5
21Contact Closing Bounce Timems≤ 2(40kA ≤ 3)
22Three-phase Open/Close Non-simultaneityms≤ 2
23Average Opening Speed (Contact Separation - 8mm)m/s1.5±0.2
24Average Closing Speed (8mm - Contact Closure)m/s0.8±0.2
25Main Circuit ResistanceμΩ<50 (630A) ≤ 45 (1250A) ≤ 35 (1600-2000A) ≤ 25(2500A and above)
26Rated Operating SequenceOpen-0.3S-Close-Open 180S-Close-Open


Appearance and Installation Dimensions

2-1.jpg